PC-DWT | Oil-operated pressure calibration
The Pacorr PC-DWT Dead Weight Tester establishes reference pressure using calibrated weights and a piston-cylinder assembly. It helps calibration laboratories, maintenance workshops and quality-control teams compare compatible pressure gauge readings at selected calibration points.
- Pressure generation Priming pump and screw ram
- Calibrated weights Non-magnetic stainless steel
- Configuration options Single or dual piston
- Documentation Traceable calibration certificate
Explore the specifications, included accessories and optional configurations below, or request a PC-DWT quotation.
- Shipping Area: All over the world
- Model: PC-DWT
- Brand: Pacorr
- Availability: In Stock
Overview of the Pacorr PC-DWT
Pressure gauge calibration requires a reference matched to the instrument's working range and calibration requirements. The PC-DWT combines a priming pump and screw ram for pressure generation with calibrated, non-magnetic stainless steel weights.
Single- and dual-piston configurations are available. Select the piston arrangement, weight set and pressure units to match the gauges you intend to calibrate. Included BSP adaptors, levelling equipment, tools and a traceable calibration certificate support setup and calibration work.
Applications
- Calibration laboratories: Compare compatible gauge indications with reference pressure at selected points.
- Industrial maintenance workshops: Check gauges during scheduled maintenance or after servicing.
- Manufacturing quality-control departments: Verify pressure gauges used in production and inspection.
- Instrument service facilities: Evaluate gauge readings before and after adjustment or repair.
Suitability depends on the gauge's pressure range, connection and compatibility with the operating oil.
Selecting Your PC-DWT Configuration
Begin with the lowest and highest pressure points you need to calibrate. Identify the required pressure units, gauge connection and calibration tolerance. Share these details with Pacorr to establish the suitable piston arrangement and weight set.
Include requirements for smaller pressure increments, alternative adaptors, software, motorisation and calibration documentation.
Frequently Asked Questions
What is the Pacorr PC-DWT used for?
The PC-DWT calibrates compatible pressure gauges by comparing their indications with reference pressure established using calibrated weights and a piston-cylinder assembly. It supports laboratory, maintenance and quality-control calibration work.
What pressure options are listed for the PC-DWT?
Pacorr lists 35, 70, 100, 160, 350, 600 and 700 bar options. The usable pressure interval and available increments depend on the selected piston and weight configuration. Confirm these against your required calibration points before ordering.
Does the PC-DWT use oil or compressed air?
The specified operating fluid is oil. The standard accessories include 500 ml of operating fluid. Confirm that the gauge and its wetted components are compatible with the specified oil before connecting them.
Which gauge adaptors are included?
The standard accessory set includes 1/8, 1/4, 3/8 and 1/2 inch BSP adaptors. A right-angle adaptor and two-gauge adaptor are optional. Include the gauge thread size and connection details in your enquiry.
Is a calibration certificate supplied?
Yes. A traceable calibration certificate is included. If your purchasing procedure requires an accredited certificate, specify the required pressure range and documentation so the issuing laboratory and applicable scope can be confirmed.
Can the tester be supplied in different pressure units?
The listed options include bar and psi, with kPa and MPa available optionally. Conversion weight sets are also optional. Specify your required units before ordering so the weight set and calibration documentation match your application.
Are calibration software and a motorised version included as standard?
No. DWT calibration software and the motorised version are optional. Request them separately and confirm their functions and configuration requirements with Pacorr.
What maintenance does the PC-DWT require?
Follow the supplied instruction manual for fluid care, cleaning, seal inspection and storage. Use the supplied dust cover and weight-set carrying case as directed. Confirm the recommended oil grade, service procedure and recalibration interval with Pacorr for your operating conditions.
Request a Dead Weight Tester Quotation
Contact Pacorr for a PC-DWT quotation matched to your application. Include your gauge type, calibration pressure points, preferred units, connection size, certificate requirements and delivery country.
Request a PC-DWT quotationLearn more about Pacorr Testing Instruments or explore Pacorr testing instruments.
Write Your Review
Get a Quote
Share your requirement and our team will reply shortly.
+91-8882149230
Our Clients
Our USP's
Demonstration of Machine
- Try Before You Decide
- Experience Before You Invest
- See It in Action – Free Demo
Global Reach
- Delivering Excellence Worldwide
- Serving Across Borders
- Your Global Supply Partner
On-Site Support
- Support That Comes to You
- On-Ground Assistance, Anywhere
- We Reach Where You Are
Team Strength
- Powered by Expert Minds
- Driven by Skilled Professionals
- Engineering Excellence Team
Manufacturing
- Precision-Driven Manufacturing
- Smart & Automated Production
- Engineered In-House Excellence