Complete Plastic and Polymer Testing Lab Setup: Equipment, Cost and Standards

A practical plastic and polymer testing lab starts with the material, the specimen and the result that drives a decision. A resin buyer may need an extrusion plastometer and a moisture method. An injection moulding plant may need tensile, impact and thermal tests on defined specimens. A film converter may need thin-sheet tensile testing, falling-dart impact and coefficient of friction. Those stations are not interchangeable simply because the material is plastic.

Use the Pacorr plastic and polymer testing instruments category to shortlist equipment after mapping the tests that control receipt, production or release. The real setup cost includes tooling, verified measurement ranges, specimen preparation, site work, commissioning and operation. This guide explains how to build that list, compare quotations and check that the installed lab can produce usable results.

What equipment does a plastic and polymer testing lab need?

Separate the lab into three specimen streams. Incoming resin includes pellets, powder or regrind. Moulded or machined test pieces represent a material, process or part according to the product specification. Film strips come from an identified position and direction on a roll or web. A finished assembly, pipe or multilayer package may require an application-specific test in addition to the material tests below.

Rows map resin pellets to melt flow or density, moulded parts to tensile or impact, and film to tensile or friction tests.
These are example decisions by specimen family. Choose only the tests, configurations and reporting units required by the approved product specification.
Specimen or decision Equipment and checks to consider
Incoming resin or compounded pellets Balance and sampling tools, approved moisture or water-content method where relevant, extrusion plastometer for specified melt flow, and density or identity checks where required.
Moulded material coupons or part specimens Universal testing machine with suitable load cell, grips and strain measurement. Add verified impact fixtures, notch preparation and thermal testing when the specification requires those results.
Extruded or converted film Suitable film grips or film tensile tester, precise thickness gauge and strip cutter. Add a dart impact station or coefficient of friction fixture if those results drive release.
Shared laboratory work Traceable dimensions and mass, conditioning, sample storage, data capture, equipment checks and controlled report review.

Build a method register before asking for a price. Record the material grade, specimen form, method edition, dimensions, conditioning, measured endpoint, units and limit owner. Add expected ranges, release frequency and sample peak volume. Use a separate row for each decision. A single test frame can support several methods only if each configuration has the right fixtures, sensing and verification.

How should incoming resin and moisture be checked?

Start with the supplier designation, batch identity, certificate requirements and packaging condition. Draw samples under the approved plan and keep a retained portion when the quality system requires one. A certificate comparison can verify documentation but does not itself establish that a bag contains the correct resin. Where grade or polymer identification is a meaningful risk, use an approved identification approach. For example, infrared spectral comparison can screen polymer-family identity against suitable references. One matching spectrum does not automatically establish an exact commercial grade, filler loading or melt-flow range.

Keep incoming moisture and moisture at the point of processing separate. Pellets can pick up water in handling between a dryer and the moulding or extrusion line. Use a representative sample, a suitable sealed container and the timing defined by the procedure. A loss-on-drying moisture analyser measures a mass change that can include other volatile loss. A requirement for water content may need a different, suitably validated method. Water absorption after immersion addresses another question and should not be used as a synonym for incoming pellet moisture.

Do not label a density or melt-flow result as definitive proof of identity. Filler, blends and changes in processing history can alter results, and different grades can have overlapping values. Agree the release and hold rules before testing. If a large delivery contains different supplier lots, retain the link between each measurement and the correct lot rather than averaging everything as one shipment.

How do you distinguish MFR, MVR and a commercial melt index?

An extrusion plastometer measures flow through a standard die under specified test conditions. Melt mass-flow rate, or MFR, is reported in g/10 min. Melt volume-flow rate, or MVR, is reported in cm³/10 min. The term melt flow index or MFI commonly refers to the mass result in trade usage, but a purchase specification should name the quantity, test method and conditions rather than relying on the abbreviation alone. An MVR reading is not numerically interchangeable with an MFR reading.

ASTM D1238 specifies melt-flow test procedures for thermoplastics using an extrusion plastometer. ISO 1133-1 gives a standard method for MFR and MVR, with mass and displacement measurement procedures. ISO 1133-2 addresses materials sensitive to time–temperature history and/or moisture. ASTM D1238 and ISO 1133 address similar measurements, but they differ technically. Pick the method and procedure named by the purchaser or material standard. A tester with a matching maximum temperature does not prove that its configured timing, load, die, displacement sensing or sample handling meets the chosen procedure.

What does a melt-flow calculation look like?

In a hypothetical mass measurement, an accepted cut portion weighs 0.36 g over 30 s. Multiplying 0.36 by 600 and dividing by 30 gives an MFR of 7.20 g/10 min. In a separate hypothetical displacement-based reading, the measured volume is 0.48 cm³ over 30 s. That gives an MVR of 9.60 cm³/10 min. The 600 is the number of seconds in ten minutes. These are illustrative calculations for two independent readings, not machine timings, equivalent values or product limits. The prescribed procedure determines which readings are valid. Conversion requires the correct melt density at the relevant test conditions, not the density of a solid pellet at room temperature.

Confirm the expected rate, test temperature and load specified for the resin, test unit, sample preparation, cleaning and approved checks. Record the temperature and load with each result. A change in load, dwell, moisture state or procedure can change a result without a change in resin grade. Use Pacorr's melt flow index tester listing and melt-flow calculation guide as starting points for a configuration discussion, not as a replacement for the method.

How do you investigate an out-of-spec melt-flow result?

Suppose a melt-flow result for a moisture-sensitive resin falls outside the applicable limit after a dryer changeover. Hold the affected material under the quality procedure. Check that the result is the required MFR or MVR and that the worksheet, instrument settings and exported units match the specified procedure. Check the recorded temperature and load, timing, die identification and condition, and whether the relevant equipment checks passed. Keep the original result and record any reason for classifying a run as invalid.

Next separate a material question from a handling question. Compare a retained incoming portion and a separately identified sample at the line, following the approved sampling and test preparation for each. Record where and when each sample was taken and how it was protected. Review the dryer records without assuming they prove the pellet state. If water content is part of the investigation, use the approved water-content method. A higher loss-on-drying result alone does not establish excess water. Do not change the drying procedure, switch flow methods or average away a valid failure to obtain a passing result. Retest and disposition only as the approved procedure permits.

Which tensile test fits moulded plastics and film?

ASTM D638 addresses tensile properties of plastics using standard dumbbell-shaped specimens under defined conditions. ASTM D882 addresses tensile properties of thin plastic sheeting with thickness less than 1.0 mm. Specimen dimensions, preparation, grips, gauge length and speed come from the selected method and material specification. The ISO 527 series likewise uses parts tailored to the material and specimen form. A film result should not be reported under a method selected only because the installed frame can pull a film strip.

What you measure What makes the result traceable
Tensile strength or stress at a specified event Identify the event, such as yield, maximum force or break, as defined by the method. Record original cross-sectional dimensions and stress units.
Elongation or strain Identify the reference length and the measurement method. Crosshead movement may include grip slip or system compliance and is not automatically specimen strain.
Tensile modulus Use the specified strain measurement, strain range and analysis procedure. Do not infer modulus from peak force or from a single stress-at-break value.

For an illustrative calculation only, a valid tensile specimen with an original width of 10.0 mm and thickness of 4.0 mm has an original cross-sectional area of 40.0 mm². A maximum force of 1,200 N divided by that area gives 30.0 N/mm², or 30.0 MPa, for an engineering stress at maximum force. This is not automatically the stress at break. The dimensions do not specify a universal specimen type, and the result is not an acceptance limit.

Choose grips for the specimen rather than by frame rating alone. Film may need suitable lightweight gripping arrangements and alignment that prevent slipping or jaw damage. Moulded pieces may need another grip design and extensometer travel. Consider the Pacorr tensile testing machine range alongside the ASTM D638 and D882 method comparison. Ask the supplier to demonstrate both specimen types when both are in scope.

What should you check when film repeatedly breaks at the grip?

If several strips break next to the same jaw, preserve the force traces and record where each break started. Look for damaged cut edges, jaw impressions, uneven seating and signs that a strip moved relative to the grip. Review the force and extension channels together. A trace with an abrupt change can flag possible slip or a specimen event, but the trace alone does not prove which occurred. Check the approved rule for reporting or rejecting each affected result instead of dropping every grip break automatically.

For troubleshooting, compare newly prepared strips from adjacent positions on the same roll, within the approved sampling plan. Keep machine-direction and transverse-direction groups separate and use verified dimensions, conditioning and the approved setup. Check whether the fracture pattern follows the same jaw or remains tied to a web position or direction after the setup checks. If a different grip or preparation tool is needed, verify that configuration before using it for release tests. Do not compare a suspect extension result directly with a confirmed specimen-strain reading.

How are Izod, Charpy, HDT, Vicat and density different?

Izod and Charpy are pendulum impact configurations, not interchangeable names for one measurement. Izod holds a test piece as a cantilever. Charpy supports a test piece at both ends. Check the applicable method for dimensions, notch, positioning, impact direction, pendulum and break classification. ASTM D256 covers Izod impact resistance of plastics and ASTM D6110 covers Charpy impact resistance of notched plastics specimens. ISO 180 covers Izod and ISO 179-1 covers non-instrumented Charpy. The applicable results may normalise energy by a specified length or area, so do not convert one method to another by changing units. Record the break type or non-break as required. Compare the Pacorr IZOD / Charpy impact tester and Izod versus Charpy guide when assessing fixtures and pendulums.

Heat deflection temperature, often shortened to HDT, is associated with a specified deflection under load during heating. ASTM D648 and the ISO 75 series address temperature of deflection under load. Vicat softening temperature uses specified indenter penetration during heating and is covered by ASTM D1525 or ISO 306 as applicable. Report temperature in °C with the method and specified load or stress and heating conditions, not as a single universal heat-resistance rating. Neither result gives a melt temperature, glass transition temperature or guaranteed service temperature. Use the Pacorr heat deformation tester listing to start a quote and confirm whether both configurations and their required accessories are included.

Density is mass per volume, commonly reported for plastics in g/cm³ or kg/m³. ASTM D792 describes displacement methods for solid plastics. Check suitability for the specimen and liquid, particularly if the piece traps bubbles, absorbs the liquid or has a porous structure. A specific gravity balance is a candidate if its configuration and verified range suit the method. In-house mass and displacement measurements may assist lot comparison, but they are distinct from bulk density of pellets and from composition or filler identification. Keep the method, specimen state, temperature information where required and units with the reading.

Which additional tests are useful on packaging film?

A falling-dart method such as ASTM D1709 estimates the dart mass associated with 50% specimen failure in a defined plastic-film impact test. It is not the load at a single puncture event, and it does not represent the drop resistance of a packed carton. Record the method variant, film thickness and orientation information required by the test. A Pacorr dart impact tester and the 50% failure-mass guide help clarify what the apparatus and result represent.

Coefficient of friction, or COF, describes resistance to sliding for a defined pair of contacting surfaces. The static and kinetic quantities address different parts of the motion and are dimensionless. ASTM D1894 addresses static and kinetic coefficients of friction of plastic film and sheeting. Record the contact pair, which side of the film faces the mating surface, conditioning and direction where specified. A low coefficient is not automatically suitable for every conveyor or winding process. Before specifying a Pacorr COF tester, see the static and kinetic COF guide for the difference between the two outputs and compare actual contact conditions.

Other applications may also call for tear resistance, sealing strength or barrier performance. Select them after identifying the likely failure and the required specimen. Film tensile behaviour in one direction, for instance, does not establish seal integrity or oxygen transmission. Keep the optional list separate from the tests that decide routine release.

How do you match the instrument to the actual test range?

Ask the supplier to identify both the capacity and the verified usable range for the assembled configuration. A large load cell may not be the right choice for thin film if the important forces occur near the bottom of its verified range. A small load cell may not survive a rigid tensile job. Account for fixture limits, test speed, usable travel after fitting grips and the strain sensor’s range. On an impact instrument, ask which pendulum and fixtures cover the intended specimen and expected energy. On a thermal station, request the available stress or load arrangements, controlled heating conditions and meaningful temperature range for the named methods.

Two schematic tensile setups compare a moulded plastic dog-bone specimen and a flat plastic film strip held between grips, with arrows showing opposite pulling directions.
These schematic shapes are not cutting templates. Confirm the standard, grips, load measurement and strain measurement for the material being tested.

Test against your actual extremes during the demonstration. Bring a low-force film specimen and a higher-force coupon if the same frame will serve both. Compare the force or energy units shown on screen and in the exported file. Ask for a representative trace, not just a peak value, to check whether the desired endpoint is recorded. List what is in the base offer and what requires a separate sensor, fixture, cutting tool, method module or licence. A specification sheet for the frame should not be taken as a test report for the fitted system.

How should you prepare and condition the specimens?

Define how specimens are made, sampled and identified before they reach the machine. Moulding, machining and punching can introduce different edges, thickness variation and process history. An unmarked piece taken from a finished component cannot automatically stand in for a moulded standard bar. Preserve the cavity or tool identifier, grade, batch and specimen orientation. Where a cut from a part is permitted, use the exact location and preparation procedure required and record it.

A film sheet diagram shows machine-direction and transverse-direction strips cut at right angles and marked separately.
Mark the axis on the parent film and each specimen where the method permits. Keep direction, specimen preparation and the specified conditioning linked to each result.

For film, label the machine direction and transverse direction before cutting. Retain the roll identifier, position and side orientation when needed. Check strip width and thickness with suitable tools and avoid curled, stretched or damaged edges caused by cutting. Take and report directional groups separately where required. For notched impact, verify the notch profile and remaining section as specified. A damaged or inaccurate notch can dominate the measured fracture response and should not be treated as a property of the base resin.

ASTM D618 covers conditioning plastics for testing. Apply the conditioning and test atmosphere required by the applicable method or material specification rather than assuming a universal time, temperature or humidity. Keep material drying for processing separate from conditioning for measurement. Label freshly prepared, dried and conditioned specimens so the result cannot be matched to the wrong state. Record deviations, test timing and supports where needed rather than describing the specimens as conditioned without evidence.

What should you buy first for your production line?

A resin or compounding plant should start with its incoming and outgoing grade decisions. That can include sampling, mass, a specified melt-flow method and a moisture or density method when release depends on them. A moulding plant often starts with its controlled mechanical specimens and verified dimensional checks. If customers require impact or thermal results before release, those methods belong in the first phase rather than on an optional wish list.

A film converter should start with representative roll sampling, a thickness gauge and a correctly configured film tensile setup if those are the release checks. Add COF, dart impact or sealing measurements where specifications or recurring failures justify them. A lab can use accredited external services for infrequent specialist methods if the contract and turnaround allow it. Keep responsibility for packaging the specimens, reporting the exact method and handling a nonconforming result explicit.

Compare capacity at the busiest point, not the average day. Cutting, conditioning, line sampling, fixture changes and review can consume more time than the test stroke. Decide whether delays call for another shift, a second fixture, parallel conditioning space or another instrument. A change in part range may justify a different load cell rather than a whole second frame. Require a demonstration of realistic changeover and data capture before buying for projected throughput.

How can you estimate whether one station can keep up?

In a hypothetical peak window, 18 ready-to-test specimens each occupy a frame for three minutes, including mounting and unloading. Two fixture changes take eight minutes each. The booked frame time is 18 × 3 + 2 × 8 = 70 minutes. That would leave 20 minutes in a 90-minute window before any extra checks or unplanned delays. These are planning numbers, not test settings or a throughput guarantee. Track conditioning, preparation and result review separately. A second frame will not solve a delay if conditioned specimens or the approving operator are the bottleneck.

How much does a plastic and polymer testing lab setup cost?

There is no meaningful one-price estimate for every plastics lab. An incoming-resin station with one melt-flow procedure is not comparable to a facility that also tests moulded impact bars, HDT and multi-directional film. Request written quotes in INR for the named methods, let the supplier state what is included and compare offers at equivalent scope. A headline machine price without tooling, verification or software can be misleading.

Three-year worked example shows 135 installed planning units plus 45 running units equals 180 total units. These are not quoted prices.
The running amount represents 15 illustrative planning units each year for three years. Include fixtures, installation and verification when comparing equipment quotes, along with recurring service and consumables.
Cost area Items to include in the comparison
Installed equipment Frame and sensors, fixtures, gauges, cutters, preparation tools, verified reference equipment, commissioning and training.
Site readiness Workbenches, conditioning or segregation, extraction, electrical and other services, handling and facility changes.
Recurring ownership Verification and calibration, consumables, service, software, operator time and external tests that remain outside your scope.

In a hypothetical ownership comparison, assign 100 planning units to core machines, 20 to fixtures and specimen preparation, 9 to site work, and 6 to initial verification and training. The installed total is 135 units. If recurring costs are 15 units each year, the simple three-year total is 135 + 3 × 15, or 180 units. These numbers are arithmetic only, not percentages, prices or currency figures. Put actual taxes, freight, support, service terms and any expected downtime on the same basis for all quotations. Note what has been excluded so later readers can reproduce the comparison.

How should a plastics lab be laid out?

Plan a route from goods receipt and labelled sample storage through preparation, conditioning, testing and retained specimens. Keep the balance, gauges and conditioning work away from dust, vibration, heat and moving stock. Specimen machining, cutting and notching need a dedicated preparation area and a safe route for waste. Keep hot extrusion plastometers and thermal testing equipment out of the climate-sensitive measurement area. Give pendulums and other moving apparatus the guarding and access required by the selected equipment and facility assessment.

Specimen traceability flow connects intake lot and grade, specimen preparation and IDs, conditioning records, and the instrument and result reported.
Keep intake records, specimen identity and conditioning history linked to each result. The flow is conceptual, not a floor plan or a requirement for one room per step.

Separate lots awaiting approval from released or retained specimens. Assign locations for clean fixtures, dies, weights and reference pieces so that operators do not reach for a similar but incorrectly identified item. Match the workbench and access route to the instrument footprint and the safe handling of samples and accessories. Provide a clean report station or a controlled network destination for records. Avoid putting the only dimensional station where routine sample preparation will disturb readings.

What site requirements should be checked before installation?

Request a model-specific site sheet. Check installation dimensions, mass, bench or floor capacity, service clearances, power and earthing, and any ventilation, compressed air or liquid services required for the chosen options. Ask which party supplies cables, extraction, guards, conditioning equipment and reference tooling. Do not infer utilities from the machine category or improvise site connections based on another lab’s model.

Site readiness checklist shows a stable bench, electrical supply check, ventilation and heat load, equipment access and clearance.
Check installation drawings and supplier service requirements for the selected instruments. Separate precision measurements from noisy or hot preparation work.

Use trained site personnel and the manufacturer instructions to plan hot surfaces, moving parts, impact shields and the handling of heated or pressurised systems. Determine how extraction, spills and waste will be managed for your actual materials and methods. Check whether staff need room to operate open guards safely with the machine isolated. Confirm data connectivity and file naming before the acceptance trial. Installation is not complete merely because the instrument powers on.

How do you commission the lab and verify the methods?

Write a receiving and acceptance checklist before ordering. Match the machine, sensor, fixture and software identities to the quote. Inspect the supplied dies, dimensional tools, notch tools or reference pieces as applicable. Check that calibration or verification covers the actual working range and quantities used, such as force, temperature, time, displacement and mass. Run approved methods on representative specimens under trained supervision. Confirm the test result, trace, units and export all agree with the documented method.

Four commissioning stages check the actual delivered instruments, calibration coverage, trial specimens and method approval.
Use representative trial specimens and verify the required ranges, fixtures, records and operator instructions before routine release. Calibration alone does not establish method readiness.

For routine operation, define interim checks, responsibilities and service intervals appropriate to the methods and risk. Use references and representative repeat trials to see whether the measurement system distinguishes a meaningful change. Destructive tests require separate comparable specimens and a study design that accounts for specimen variation. If an interim check fails, identify the affected jobs and investigate before releasing further results. Keep deviation, corrective-action and authorisation records with the instrument history.

ISO/IEC 17025 addresses competence, impartiality and consistent operation of testing and calibration laboratories. It is not a polymer acceptance specification. Owning an instrument or having a calibration certificate does not make the lab accredited. Where an accredited result is required, check the provider’s scope for the specific method and relevant measurement capabilities.

How do you transfer a method from a supplier or external lab?

Agree the exact method edition, material condition, specimen origin and endpoint before comparing results. For a hypothetical film station that needs to measure from 8 to 18 N, a proposed force channel verified only from 20 N upward does not cover those measurements, even if the frame has ample capacity. Ask for evidence covering the intended range and verify the configured channel when commissioning.

For the comparison itself, assign equivalent specimens from a common lot to both labs. For destructive tests, use separate specimens and keep cutting direction, sampling position and conditioning comparable. Agree how results will be compared and accepted before the trial. Preserve individual readings and investigate differences in thickness measurement, strain sensing, fixtures or software definitions before combining data. A calibration certificate or one coincident result does not establish that the two labs can apply the same release rule interchangeably.

What should a polymer test report and supplier enquiry include?

Record the product and lot identifier, specimen origin, geometry and orientation, preparation, conditioning, method edition or approved revision, fixture or sensor ID, individual readings and required summary. Identify the units and endpoint. Include observations such as grip slip, an incomplete break or a test stopped before the required endpoint. Handle invalid results under the approved procedure and distinguish them from valid results below a release limit. Agree whether limits apply to individual readings, a mean or another statistic before issuing a decision.

For a Pacorr quotation, prepare a list of resin grades, part geometries, film thicknesses, sample volumes and required methods. Add the expected low and high ranges, useful exports, equipment location and the desired factory and site acceptance checks. Put fixtures and preparation tools on the same list, including those you already own. Contact Pacorr for an itemised proposal for the selected lab scope, installation, verification and support.

Frequently asked questions

What is the minimum equipment for a polymer quality-control lab?

Start with the release decisions, suitable sample preparation and basic dimensional and mass measurement. Add the specified station for each decision. An incoming-resin lab, a moulded-plastics lab and a film lab may need different first purchases.

Are melt mass-flow rate and melt volume-flow rate interchangeable?

No. MFR is in g/10 min and MVR is in cm³/10 min. Report which result was measured and state the conditions. Conversion requires the appropriate melt density and comparable test conditions.

Can I use ASTM D638 for film instead of ASTM D882?

Select the method required for the specimen and specification. D638 uses standard dumbbell specimens for tensile testing of plastics, while D882 addresses thin plastic sheeting within its scope. Shared machine operation does not make the results interchangeable.

Can one pendulum tester perform both Izod and Charpy?

Some configurations can accommodate both, but only with appropriate fixtures, pendulums, positioning and verification for each method. Confirm both configurations in the quotation. Do not use an Izod result as a substitute for a Charpy result.

Are HDT and Vicat the same temperature?

No. HDT uses a defined deflection under load, while Vicat uses specified indenter penetration during heating. Report the method and test conditions with the result. Neither gives a universal maximum service temperature.

Do we need to repeat the test in both directions for film?

Use the directions prescribed by the governing method and product specification. Identify machine and transverse groups before cutting. Keep the results separate when the release or reporting rule distinguishes them.

What is the cost of a complete plastic and polymer testing lab in India?

There is no reliable universal price. Compare scope-based INR quotations that list fixtures, preparation, conditioning, site services, commissioning and ongoing costs. Identify methods that can remain outsourced and request a demonstration on actual samples before finalising the equipment list.

Does equipment calibration make the plastics lab accredited?

No. Calibration or verification supports the measurement, while accreditation addresses the laboratory’s competence for an identified scope. If the customer requires an accredited result, verify scope coverage for the particular method.

Our USP's

01

Demonstration of Machine

  • Try Before You Decide
  • Experience Before You Invest
  • See It in Action – Free Demo
02

Global Reach

  • Delivering Excellence Worldwide
  • Serving Across Borders
  • Your Global Supply Partner
03

On-Site Support

  • Support That Comes to You
  • On-Ground Assistance, Anywhere
  • We Reach Where You Are
04

Team Strength

  • Powered by Expert Minds
  • Driven by Skilled Professionals
  • Engineering Excellence Team
05

Manufacturing

  • Precision-Driven Manufacturing
  • Smart & Automated Production
  • Engineered In-House Excellence
Testimonials

What Our Customers Say

Thanks to Pacorr Testing instruments, we have all the required quality testing instruments that have helped us to ensure the best quality delivered to our clients.

D

Danish

Fair Exports Pvt. Ltd.

The extensive range of testing instruments they have to offer, satisfied all my quality testing needs. The most impressive things, I feel, is the comprehensive after-sales support that I received from them.

NJ

Nipun Jain

Fast Pack India

I recently ordered some plastic molding testing instruments from Pacorr and I must say I am amazed by the quality of their devices and the support we got from their team was remarkable. I totally recommend Pacorr instruments for unmatched quality assurance.

BS

Bhaskar Srivastava

Dipty Lal Judge Mal Pvt Ltd

Pacorr has offered us the best range of chemicals and coating testing instruments that have made it extremely easy to take care of our product quality. Thanks Pacorr Testing Instruments.

RD

Rajpal Dhiman

Tasmay Unicoats Private Limited

I purchased a torque tester for my company which is working just perfectly fine since last 6 months. Also, their comprehensive after sales service makes them stand out from others. I will recommend Pacorr for best quality products and excellent customer service.

AJ

Mr. Anuj Jakhodia (Director)

Safe Closures LLP

WhatsApp